Only the first 1024 bytes of the GSD file are displayed within the preview.
#Profibus_DP
GSD_Revision=2 ;Change to 1 and remove 45.45kbit items if there are problems
Vendor_Name = "Mitsubishi Electric Corp."
Model_Name = "FX0N-32NT-DP"
Revision = "MEU-GER V1.02 / PCN modified"
Ident_Number = 0xF032
Protocol_Ident = 0
Station_Type = 0
FMS_supp = 0
Hardware_Release = "B"
Software_Release = "V1.01 / PCN modified"
9.6_supp = 1
19.2_supp = 1
;45.45_supp = 1 ; Enable if this baudrate is required
93.75_supp = 1
187.5_supp = 1
500_supp = 1
1.5M_supp = 1
3M_supp = 1
6M_supp = 1
12M_supp = 1
MaxTsdr_9.6 = 60
MaxTsdr_19.2 = 60
;MaxTsdr_45.45 = 60 ; Enable if this baudrate is required
MaxTsdr_93.75 = 60
MaxTsdr_187.5 = 60
MaxTsdr_500 = 100
MaxTsdr_1.5M = 150
MaxTsdr_3M = 250
MaxTsdr_6M = 450
MaxTsdr_12M = 800
Redundancy